Product Description
-------------------
The MediTouch 2 test strips are based on an improved enzyme
composition (GDH-FAD), which reacts with glucose specifically and
thus, minimises the influence of other substances. In addition,
the test strips have an under filling detection feature which
prevents measurement if the blood sample is not sufficient. Thus,
MediTouch 2 provides more accurate measurement results and offers
es patients a feeling of assurance that they are getting
optimal support in their management. Equipped with several
other useful features, such as average value calculation, test
reminders and marking meal times, MediTouch 2 is the optimal
companion for your day-to-day life when you have es. Under
filling detection, USB port for data transfer, Pre and post meal
markers, Acoustic test reminder, Calculates average values for
7/14/30/90 days, 480 memory slots, Automatic ketone warning,
Starter set includes lancing device, AST cap, 10 lancets, 10 test
strips, control solution and bag, Measuring time within 5 seconds
0.6 µL blood, Extra large, easy-to-read display, 3 year
guarantee, Approximate size: 5 cm by 9.8 cm by 1.2 cm. 2 x 3 V
batteries.
Directions
----------
Only use these with the MediTouch monitor. Store the test strips
in their original container. To avoid contamination, only touch
the test strips with clean, dry hands. When removing the strips
from the container and inserting them in the monitor, only touch
them using the grip (holder). Close the container again
immediately once you have removed the test strip. This keeps the
test strips dry and free of dust. Use the test strip within three
minutes of removing it from the container. The test strip is
intended to be used only once. Do not use it again. Write the
opening date on the label of the container when you open it for
the first time. Observe the expiry date. The test strips can be
used for approx. three months after opening the container or
until the expiry date, whichever comes first. Do not use test
strips which have already exceeded the expiry date, as this can
distort the test result. The expiry date is printed on the
container. Store the test strips in a cool, dry place but not in
the refrigerator. Store the test strips between 2 °C and 30 °C
(35.6 °F - 86 °F). Do not freeze the test strips. Protect the
strips from damp and direct sunlight. Do not apply the blood
sample or control solution to the test strip before you have
inserted it in the monitor. Only apply the blood sample or the
control solution provided on the test strip slot. Applying any
other substance will lead to an imprecise or incorrect reading.
Do not bend, cut or adjust the test strips in any way. Keep the
container with the test strips away from children. There is a
risk of choking from the lid. The lid also contains desiccative
substances which could be dangerous if they are inhaled or
swallowed. This could also lead to skin and eye s.
P.when('A').execute(function(A) {
A.on('a:expander:toggle_description:toggle:collapse',
function(data) {
window.scroll(0, data.expander.$expander[0].offsetTop-100);
});
});
Safety Warning
--------------
Used test strips and lancets are considered to be hazardous,
biological non-biodegradable waste. Carelessness when disposing
of these items can lead to the spread of infection. If necessary,
consult your local waste disposal company, your doctor or
cist. Dispose of your used test strips and used lancets
carefully. If you dispose of the used parts with the household
rubbish, make sure you wrap them first to avoid harming or
infecting other people. Medical staff or others who use this
monitor on more than one patient must be aware that all products
or objects which come into contact with human blood must be dealt
with as if they are capable of spreading viral diseases, even
after cleaning. Never use a lancet or the lancing device on more
than one person. Use a new sterile lancet and a new test strip
for every test. Lancets, test strips and alcohol pads are
disposable. Avoid getting hand cream, oil or dirt in or on the
lancet, lancing device and test strip.
Box Contains
------------
Each order comes with 1 x MediTouch Blood Glucose Monitor with
Starter Set
See more ( javascript:void(0) )
- Precise readings The blood glucose meter combines an attractive design and a high level of user friendliness. In accordance with ISO 15197 and test strip technology, the medical device provides precise measurement values in mmol/L.
- Quick results A blood volume of 0.6 μl and a measurement time of around five seconds are enough to obtain accurate readings.
- Integrated memory The MediTouch two blood glucose meter from Medisana is equipped with an integrated memory, which can store up to 480 measurement results. The blood glucose meter also provides average values for the last 7/14/30/90 days.
- VitaDock+ app For sustainable monitoring, the measured blood sugar levels can be transferred to the VitaDock+ app, stored and analyzed via USB data transmission.
- Functional Equipped with many other useful functions such as an average value calculation, acoustic test reminder, meal marking, and automatic ketone warning, MediTouch Two is an ideal companion for your daily es routine.
- Be careful not to touch the protruding tip while inserting the test strip into the device. The first drop of blood should not be used for measurement. In addition, no blood should get on the top of the test strip. Please dispose of the lancets immediately after use and do not reuse them..